Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Braz Oral Res ; 23(1): 68-75, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19488475

RESUMO

The aim of this study was to evaluate the following acrylic resins: Clássico, QC-20 and Lucitone, recommended specifically for thermal polymerization, and Acron MC and VIPI-WAVE, made for polymerization by microwave energy. The resins were evaluated regarding their surface nanohardness and modulus of elasticity, while varying the polymerization time recommended by the manufacturer. They were also compared as to the presence of water absorbed by the samples. The technique used was nanoindentation, using the Nano Indenter XP, MTS. According to an intra-group analysis, when using the polymerization time recommended by the manufacturer, a variation of 0.14 to 0.23 GPa for nanohardness and 2.61 to 3.73 GPa for modulus of elasticity was observed for the thermally polymerized resins. The variation for the resins made for polymerization by microwave energy was 0.15 to 0.22 GPa for nanohardness and 2.94 to 3.73 GPa for modulus of elasticity. The conclusion was that the Classico resin presented higher nanohardness and higher modulus of elasticity values when compared to those of the same group, while Acron MC presented the highest values for the same characteristics when compared to those of the same group. The water absorption evaluation showed that all the thermal polymerization resins, except for Lucitone, presented significant nanohardness differences when submitted to dehydration or rehydration, while only Acron MC presented no significant differences when submitted to a double polymerization time. Regarding the modulus of elasticity, it was observed that all the tested materials and products, except for Lucitone, showed a significant increase in modulus of elasticity when submitted to a lack of hydration.


Assuntos
Resinas Acrílicas , Elasticidade , Teste de Materiais , Resinas Acrílicas/química , Dureza , Testes de Dureza , Temperatura Alta , Humanos , Micro-Ondas , Propriedades de Superfície , Fatores de Tempo
2.
J. Health Sci. Inst ; 27(2)abr.-jun. 2009. ilus, tab
Artigo em Português | LILACS | ID: lil-541592

RESUMO

Introdução - Na reabilitação protética, a oclusão e os movimentos mandibulares estão intrinsecamente ligados. Um dos conceitos sempre abordados na busca deste ideal é a relação entre os sulcos e as cúspides dos dentes com os movimentos mandibulares, que deve permitir um deslizamento livre de interferências entre ambos. Assim, foi proposto avaliar o grau de coincidência da angulação do sulco de trabalho do primeiro molar inferior artificial, quando posicionado no arco, em relação à trajetória descrita pela cúspide mésio-palatina do primeiro molar superior em relação ao eixo de rotação vertical de lateralidade da mandíbula no articulador semi-ajustável. Material e Métodos - Utilizou-se uma metodologia, através de um programa de editoração gráfica, que permitiu avaliar as imagens digitais de montagens em cera de dentes artificiais em prótese totais inferiores e de seus respectivos planos de orientação. Localizou-se o sulco de trabalho do primeiro molar inferior (A), a trajetória da cúspide mésio-palatina do primeiro molar superior adotando-se o eixo de rotação vertical no centro das esferas condilares (B), e a perpendicular à tangente ao plano de orientação (C). Resultados e Conclusões - Assim, mediram-se os ângulos formados entre A-C e A-B. Os resultados mostraram que houve casos onde A coincidiu com C, nos demais casos a angulação apresentou, em média, valores baixos, demonstrando que os parâmetros adotados para a montagem dos dentes artificiais foram seguidos. Não foi observada a coincidência entre A e B, indicando que, durante a reprodução do movimento de lateralidade no articulador, ocorre interferência na excursão da cúspide mésio-palatina do primeiro molar superior.


Introduction - In prosthetic rehabilitation, occlusion and mandibular movements are closely linked. Harmony between these factors is essential for treatment success. Therefore, the present study proposes to evaluate the degree of coincidence of the working groove angulation from the artificial mandibular first molar, when positioned on the arch, with the trajectory traced by the mesio-palatal cuspid from the maxillary first molar during mandibular lateral translation determined by the vertical axis rotation in a semi-adjustable articulator. Material and Methods - To identify this trajectory, it was utilized a graphical editing program. It was possible to evaluate digital images from artificial teeth mounted on wax for mandibular complete dentures, and their respective orientation planes positioned on the articulator. Through these images, the author located the working groove from the mandibular first molar (A), the trajectory described by the mesio-palatal cuspid from the maxillary first molar considering the vertical axis rotation at the center of the condilar spheres (B), and the perpendicular to the tangent of orientation plane (C). Results and Conclusions - Thus, the angle between A-C and the angle between A-B were measured. The results showed some cases where A coincided with C. In the remaining cases, the angulation displayed low mean values, illustrating that the mounting of artificial teeth followed the parameters adopted for the orientation plane according to the proposed technique. The coincidence between A and B was not observed, indicating that, during the lateral translation movement in the articulator, there is interference in the trajectory of the maxillary first molar mesio-palatal cuspid.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Oclusão Dentária , Dente Artificial , Diagnóstico Bucal
3.
Braz. oral res ; 23(1): 68-75, 2009. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-514644

RESUMO

The aim of this study was to evaluate the following acrylic resins: Clássico®, QC-20® and Lucitone®, recommended specifically for thermal polymerization, and Acron MC® and VIPI-WAVE®, made for polymerization by microwave energy. The resins were evaluated regarding their surface nanohardness and modulus of elasticity, while varying the polymerization time recommended by the manufacturer. They were also compared as to the presence of water absorbed by the samples. The technique used was nanoindentation, using the Nano Indenter XP®, MTS. According to an intra-group analysis, when using the polymerization time recommended by the manufacturer, a variation of 0.14 to 0.23 GPa for nanohardness and 2.61 to 3.73 GPa for modulus of elasticity was observed for the thermally polymerized resins. The variation for the resins made for polymerization by microwave energy was 0.15 to 0.22 GPa for nanohardness and 2.94 to 3.73 GPa for modulus of elasticity. The conclusion was that the Classico® resin presented higher nanohardness and higher modulus of elasticity values when compared to those of the same group, while Acron MC® presented the highest values for the same characteristics when compared to those of the same group. The water absorption evaluation showed that all the thermal polymerization resins, except for Lucitone®, presented significant nanohardness differences when submitted to dehydration or rehydration, while only Acron MC® presented no significant differences when submitted to a double polymerization time. Regarding the modulus of elasticity, it was observed that all the tested materials and products, except for Lucitone®, showed a significant increase in modulus of elasticity when submitted to a lack of hydration.


Assuntos
Humanos , Resinas Acrílicas , Elasticidade , Teste de Materiais , Resinas Acrílicas/química , Dureza , Testes de Dureza , Temperatura Alta , Micro-Ondas , Propriedades de Superfície , Fatores de Tempo
4.
RPG rev. pos-grad ; 14(2): 147-153, abr.-jun. 2007. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-529470

RESUMO

Esse trabalho objetivou analisar a disposição de tensões oclusais em overdentures com barra Dolder resiliente implanto-retida. Para tanto, utilizou-se um modelo fotoelástico com quatro implantes, sobre o qual foi construída uma infra-estrutura metálica apoiada nos dois implantes centrais e contendo uma barra Dolder, unindo-os. Foi confeccionada, então, uma prótese com material resiliente na região posterior, permitindo a movimentação comum às situações in vivo. A carga oclusal foi aplicada por meio de um modelo dentado superior em três intensidades (3, 6 e 10 kg) e em quatro posições oclusais (máxima intercuspidação, protusão, trabalho e balanceio). As imagens foram obtidas nos planos frontal e sagital, e analisadas com o auxílio do programa Leica Qwin Pro 2.3. As áreas de leitura foram: no plano frontal, região A (área disto-cervical do implante 42) e região B (área entre os implantes 32 e 42 no terço apical); no plano sagital, região de rebordo e região de mento. Os resultados permitiram concluir que: (1) a distribuição mais equlibrada de tensões ocorreu na posição de máxima intercuspidação; (2) a maior média de tensões foi encontrada na posição de trabalho; (3) em posição de protrusão, a barra recebeu a maior quantidade de tensões axiais.


Assuntos
Encaixe de Precisão de Dentadura , Revestimento de Dentadura , Implantes Dentários , Força de Mordida , Prótese Total
6.
Int J Oral Maxillofac Implants ; 21(1): 63-70, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16519183

RESUMO

PURPOSE: The aim of this article was to evaluate the survival and success of Straumann implants after immediate loading. A new method for fabricating effective definitive prostheses to immediately load implants in edentulous patients was presented. MATERIALS AND METHODS: Nine patients received 4 implants each, and resin-metal prostheses were installed less than 48 hours after implant placement. Mobility was evaluated immediately after the surgical procedures and 3 months subsequently using the Periotest. Clinical evaluation of soft peri-implant tissues was conducted monthly after the sutures were removed, and radiographs were obtained 6, 12, and 24 months after the surgery. RESULTS: The Periotest revealed statistical values that were stable, with no mobility. No signs of inflammation and/or bleeding were observed. The radiographs did not reveal any continuous areas of radiolucency beyond the first thread of the 36 implants after 24 months. None of them failed, and the success rate was 100%. DISCUSSION: It is possible to submit implants to immediate load without jeopardizing osseointegration if parameters are met, such as suitable bone quality and quantity, lack of unfavorable systemic and psychologic factors, lack of parafunctional habits, strict maintenance of prosthetic requirements, minimization of micromotion, and use of an appropriate surgical protocol. CONCLUSION: Under immediate load, osseointegration of implants is possible, and the method presented for the fabrication of resin-metal prostheses has been reliable and predictable.


Assuntos
Implantação Dentária Endóssea/métodos , Prótese Dentária Fixada por Implante/métodos , Arcada Parcialmente Edêntula/reabilitação , Adulto , Idoso , Análise de Variância , Planejamento de Prótese Dentária , Análise de Falha de Equipamento , Humanos , Arcada Parcialmente Edêntula/diagnóstico por imagem , Pessoa de Meia-Idade , Radiografia , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento , Suporte de Carga
7.
RPG rev. pos-grad ; 13(1): 69-76, jan.-mar. 2006. graf, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-529301

RESUMO

Nesta pesquisa, em 14 pacientes da Clínica de Prótese Total da Faculdade de Odontologia da Universidade de São Paulo, foi realizada, por três avaliadores clínicos experientes e calibrados, a avaliação da retenção de prótese total bimaxilar em função das características da área basal. Foram avaliadas as retenções vertical anterior, laterais direita e esquerda e póstero-anterior e as características da área basal: forma, tamanho, altura e tipo do rebordo e a consistência da fibromucosa. Por se tratarem de opiniões, os dados foram transformados em escores e submetidos à análise de variância não paramétrica, com o teste Kruskal-Wallis, e paramétrico, com o teste ANOVA. Concluiu-se que, na maxila, a retenção das próteses totais novas foi influenciada positivamente pelo tipo rebordo paralelo e pela consistência resiliente da fibromucosa, enquanto na mandíbula influenciaram o tamanho médio e a forma oval. As opiniões sobre a retenção e o grau de satisfação entre os avaliadores e os pacientes foram as mesmas.


Assuntos
Humanos , Masculino , Feminino , Adulto , Prótese Total Superior , Aceitação pelo Paciente de Cuidados de Saúde , Retenção de Dentadura , Análise de Variância , Retenção em Prótese Dentária , Prótese Total Inferior
8.
J. Health Sci. Inst ; 23(2): 151-161, abr.-jun. 2005. ilus, CD-ROM
Artigo em Inglês, Português | LILACS, BBO - Odontologia | ID: biblio-872875

RESUMO

A retenção antero-posterior de próteses totais de próteses totais para maxilas edentadas, que apresentam tecido flácido anterior, não tem apresentado resultados satisfatórios, independente da técnica de moldagem utilizada. Acreditando ser fundamental eleger uma técnica de moldagem de acordo com as diferentes compressibilidades da mucosa, uma técnica de moldagem funcional foi desenvolvida para maxilas edentadas que apresentam tecido flácido anterior. Após a moldagem preliminar com godiva, são confeccionados um modelo anatômico e uma moldeira individual com câmara de alívio na área correspondente ao tecido flácido. A moldagem é realizada em três passos: 1) A impressão é feita com silicone, objetivando adaptar a moldeira e dela remover qualquer ponto de interferência, deslocando o tecido flácido. 2) A câmara é esvaziada e uma segunda moldagem é realizada, copiando o tecido flácido sem pressão. 3) A câmara é esvaziada uma segunda vez, o molde é adaptado com uma pressão média e nesta condição, o silicone é injetado dentro da câmara, copiando o tecido flácido túrido. A retenção conseguida com esta técnica alcança um grau satisfatório, uma vez que o silicone injetado reproduz o tecido flácido, que se tornou mais túrgido com a compressão nos tecidos adjacentes e o conseqüente deslocamento de sangue para a região anterior, como ficará quando a prótese for usada fisiologicamente, e não deformado nem em repouso.


Assuntos
Prótese Total , Retenção de Dentadura , Técnica de Moldagem Odontológica , Materiais para Moldagem Odontológica , Perda do Osso Alveolar , Retenção em Prótese Dentária
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...